Spiral Staircase Diameter Calculator — BS 5395-2 Categories & Geometry

Spiral staircases follow their own standard — BS 5395-2 — which classifies every spiral by who uses it (Category A secondary domestic, B primary domestic, C semi-public/commercial) and sets minimum clear widths and walking-line goings for each. This calculator takes your diameter, floor height and category, and checks the three things that decide whether a spiral works: clear tread width, going on the walking line, and the one everyone forgets — headroom per revolution, because on a spiral you climb under yourself. When it fails, it tells you the smallest diameter that passes.

A / B / C
BS 5395-2 Categories
600mm
Min Clear Width (Cat A)
800mm
Min Clear Width (Cat B/C)
2,000mm
Headroom Under Yourself
Free Spiral Tool

Spiral Diameter Calculator

Diameter + height + category — width, going and headroom checked in one pass.

1,600mm
2,700mm
Spiral Geometry Result
PASS ✓
This spiral complies with BS 5395-2 Category B at 1,600mm diameter
700mm
Clear Width
231mm
Going @ Walking Line
193mm
Rise (14 Risers)
2,314mm
Headroom / Rev
420°
Total Rotation
Indicative geometry check to BS 5395-2 for Categories A–C (England & Wales). Public and assembly categories (D/E) and escape-route spirals need engineer-led design. The walking line is taken at the centre of the clear tread width; guarding, the 100mm sphere rule and handrail requirements apply in full. Final setting-out is confirmed at survey.
Quick Answer — At a Glance

Minimum spiral staircase sizes in the UK come from BS 5395-2, by category: Category A (secondary domestic — loft rooms, occasional access) needs a clear tread width of 600mm and a walking-line going of 145mm, workable from about 1,300mm diameter; Category B (the main staircase of a home) needs 800mm width and 190mm going — realistically 1,600mm diameter and up; Category C (offices, semi-public) needs 800mm and 230mm, pushing diameters toward 1,800–2,200mm. The hidden constraint is headroom per revolution: you pass beneath your own treads, so one full turn must climb at least ~2,000mm plus structure — which caps how gentle the rise can be on small diameters.

BS 5395-2 Categories — Reference Table

CategoryUseMin Clear WidthMin Going @ Walking LineTypical Diameter
A — SecondaryOne room, loft, occasional600mm145mm1,300–1,500mm
B — Primary domesticMain stair of a dwelling800mm190mm1,600–1,800mm
C — Semi-publicOffices, small commercial800mm230mm1,800–2,200mm
D / E — Public & assemblyShops, venues, crowds900–1,000mm250mmEngineer designed
SPIRAL STAIRCASE GEOMETRY — PLAN BS 5395-2 — 12 treads per revolution, going on the walking line WALKING LINE — centre of clear width going measured here = 2π × r(walk) × (rotation° ÷ 360) overall diameter clear tread width GOING ON THE WALKING LINE Every tread identical · must meet the category minimum: A 145mm · B 190mm · C 230mm CLEAR TREAD WIDTH Column face to balustrade: A 600mm minimum · B and C 800mm minimum (BS 5395-2) HEADROOM PER REVOLUTION One full turn must climb 2,000mm + structure — you pass under your own treads after ¾ turn Category sets the size — not the catalogue A ≈ 1,300mm · B ≈ 1,600mm · C ≈ 1,800mm+ typical diameters

The three checks in plan: clear width from the column, going on the walking line, and headroom gained per revolution.

The "it's just for the loft" trapCategory A exists for genuinely secondary access — one room, occasional use. The moment a spiral is the only way to reach a habitable floor used daily, it's Category B, and a 1,300mm Category A spiral bought online won't pass Building Control for that job. It's the spiral equivalent of the mezzanine "staff only ≠ utility" mistake: classify by real use, then choose the diameter. Not sure a spiral fits at all? Compare footprints with the rise & going calculator and the winder calculator — an L-shape with winders often beats a spiral in the same corner.

The Headroom-Per-Revolution Rule — The Constraint Nobody Sees Coming

On a straight flight, headroom is about the ceiling. On a spiral, after roughly three-quarters of a turn you're walking under your own staircase — so the height climbed in one full revolution, minus the structural depth of the treads above, must leave 2,000mm of clear headroom. With 12 treads per revolution at a 193mm rise, one turn climbs 2,316mm: subtract ~150mm of tread structure and you clear the limit — barely. Drop to a gentler 170mm rise and the same spiral fails, which is the counterintuitive result: on spirals, a steeper rise can be the compliant choice. Fewer treads per revolution (larger rotation per tread) also helps headroom, but costs going on the walking line — the calculator balances all three so you can see the trade instantly.

Spirals as fire escapes — mostly no. Spiral and helical stairs are generally not acceptable on escape routes serving members of the public, and are restricted even for staff escape — BS 5395-2 and Approved Document B both limit their use where an evacuation flow is expected. If the staircase has any escape function, size it as a conventional flight with the escape stair width calculator before falling in love with the spiral.

Spiral Staircases — FAQ

Common questions about spiral staircase sizes and UK rules.

It depends on the BS 5395-2 category: around 1,300mm for Category A (secondary access to one room), 1,600mm for Category B (the main staircase of a home), and 1,800mm+ for Category C (semi-public). Below these, either the clear tread width or the walking-line going fails. There is no single "minimum spiral size" — the use of the stair sets it.
Yes — as a Category B spiral: minimum 800mm clear tread width, 190mm going on the walking line, compliant guarding and a continuous handrail. In practice that means a diameter of about 1,600mm or more. What it can't be is a Category A "loft spiral" pressed into daily main-stair service — that's the classification Building Control checks first.
A Category B spiral occupies a circle of roughly 1,600mm diameter — about 2m² — against roughly 3.5–4.5m² for a straight flight plus landing serving the same height. The saving is real but smaller than people expect once the landing clearances at top and bottom are counted, and spirals carry daily-use trade-offs: single-file traffic and awkward furniture moves.
On the walking line — taken at the centre of the clear tread width for typical domestic spirals. Each tread's going at that line must meet the category minimum (145/190/230mm for A/B/C), every tread must be identical, and the narrow end near the column is governed by the same taper principles as winder treads.
Yes — Approved Document K points spiral and helical stairs to BS 5395-2, so a spiral designed to the correct category complies. The full package still applies: guarding to BS 6180, the 100mm sphere rule between balusters and treads, a continuous handrail, 2,000mm headroom (including under your own treads), and Building Control sign-off where the stair is part of regulated work.
Spiral & Helical Staircases by Continox

The Right Category, The Right Diameter

Steel spiral and helical staircases designed to BS 5395-2 — category classified, walking-line geometry verified in CAD, guarding to BS 6180, EN 1090 UKCA documentation included. Free survey, fixed price within 24 hours.